Meter reader

Dial readings to kWh and average watts

For an older electricity meter with five clock dials. Enter two readings and the time between them, and this works out an estimate of the energy used and the average power over that time.

Example values are filled in. Replace them with your own two readings. Nothing you enter is stored or sent anywhere.

First reading
Second reading

The two dial rows are drawings of the readings you enter, with each pointer drawn half a unit past the number so it sits between marks. The digits you enter stay the reading. On a real meter, when a pointer looks close to a mark, the dial to its right shows whether it has passed it (rule 6 below).

Time between the readings

Estimate

Energy used
61 kWh
Average power
≈ 363 W
Average per day
≈ 8.7 kWh

(40,779 − 40,718) × 1 = 61 kWh. 61 kWh ÷ 168 h × 1000 ≈ 363 W.

Rounding on the dials alone could move this by up to ± 1 kWh, or about ± 6 W on average.

How to read the dials

Safety first: read the meter through its glass. Never open the cover or break the seal.

  1. Neighbouring dials turn in opposite directions, so check which way the numbers run on each dial before you read it.
  2. Work out the dials from right to left, because each dial's answer depends on the dial to its right. Then write the digits down from left to right, in the order they appear on the meter.
  3. When a pointer sits between two numbers, write down the lower one.
  4. Between 9 and 0, write 9.
  5. The right-hand dial has no dial to its right. If its pointer is directly on a digit, write that digit.
  6. For any other dial whose pointer looks exactly on a number, look at the dial to its right. If that dial has just passed 0, write the number the pointer is on. If it has not reached 0 yet (it reads 9), write the number below.
  7. If the meter face prints a multiplier (for example "multiply by 10"), enter it as the multiplier.

Rules 1, 3, 4 and 6 follow the non-standard-meter section of Ameren's Smart Meters page, and rule 7 follows the Los Angeles Department of Water and Power's meter guide (both are listed under Sources). Rules 2 and 5 are how this page applies them, not quotations. Both guides come from United States utilities. If your own supplier gives different instructions, follow theirs. In the drawings on this site the right-hand dial turns clockwise; on your meter, go by the numbers printed on each dial.

The arithmetic

Hours
hours = days × 24 + hours, where a day is a 24-hour block of elapsed time
Register units used
units = reading 2 − reading 1 + 100,000 if reading 2 is lower than reading 1, and units = reading 2 − reading 1 otherwise. Five decimal dials give 105 = 100,000 register states, from 00000 to 99999.
Energy used
kWh = units × multiplier
Average power
W = kWh ÷ hours × 1000, because 1 kWh is 1000 watt-hours (kilo means 1000) and energy is average power times time
Average per day
kWh per day = kWh ÷ hours × 24

Assumptions

  • The meter has five dials and the plate says kWh. The right-hand dial counts register units, and each unit is worth the multiplier in kWh (1 kWh per unit when the multiplier is 1).
  • The multiplier is 1 unless you enter one from the meter face.
  • The result is an average over the whole time. A kettle that ran for three minutes and a heater that ran all night look the same here.
  • Each reading is rounded down by the dial rules, so the difference can be out by just under one unit either way. The result shows that margin, which is one multiplier's worth of kWh.
  • Both readings come from the same forward-counting register, and the change between them is less than 100,000 units. The reader assumes at most one roll-over past 99999 back to 00000. If your second reading is lower than the first, it adds 100,000 and tells you so; check both readings again if that does not fit what you know.
  • The meter counts forwards only. Meters that also record exported energy are not covered.
  • Results are estimates, shown as rounded figures (marked with ≈) or in scientific form when very large or very small.

What it leaves out

It cannot tell when in the period the energy was used, or by what. If you also run an energy monitor, its total for the same period is a useful cross-check against the meter. Your bill and your supplier's records are the reference for what you pay.

Sources

  1. Metric (SI) Prefixes, National Institute of Standards and Technology (NIST): kilo means 103, so 1 kWh = 1000 Wh.
  2. Measuring electricity, U.S. Energy Information Administration (EIA): the watt-hour definition and worked example behind energy = average power × elapsed time, used here the other way round.
  3. SP 330 - Section 4, Table 8, National Institute of Standards and Technology (NIST): the day as 24 hours.
  4. Smart Meters, Ameren (non-standard meter section): decimal dials, alternating directions, and the 9-to-0 and adjacent-dial rules.
  5. How to Read Your Electric Meter, Los Angeles Department of Water and Power: the printed meter multiplier.